24-Port 10/100Mbps with PoE + 2G TP/SFP Combo Managed Ethernet Switch WGSW-2620PV User's Manual

Página 2 - Revision

2.2.1 Desktop Installation To install the Switch on desktop or shelf, please follows these steps: Step1: Attach the rubber feet to the recessed areas

Página 3

Console Port Information interface 4.7.4 Port Controls You can change the port status. 1 Select the port by scroll the list in Port column. 2 State:

Página 4

4.7.5 Trunking The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems on a link

Página 5 - 1. INTRODUCTION

Aggregator Information When you had setup the LACP aggregator, you will see relation information in here. Trunking - Aggregator Information interfac

Página 6 - 1.4 Product Specification

trunking. 2. A link has two passive LACP ports will not perform dynamic LACP trunking because both ports are waiting for and LACP protocol packet fro

Página 7

Query A message sent from the querier (IGMP router or switch) asking for a response from each host belonging to the multicast group. Report A message

Página 8 - 2. INSTALLATION

Static MAC Address interface MAC filtering MAC address filtering allows the switch to drop unwanted traffic. Traffic is filtered based on the destina

Página 9 - 2.2 Install the Switch

MAC Filtering interface 4.7.7 VLAN configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you t

Página 10 - 2.2.2 Rack Mounting

VLAN – PortBase interface 2. Click Add to create a new VLAN group 3. Enter the VLAN name, VLAN ID and select the members for the VLAN group. 4. Cl

Página 11

5. You will see the VLAN displays. 6. If there are many groups that over the limit of one page, you can click Next Page to view other VLAN groups.

Página 12 - 3. CONSOLE MANAGEMENT

a device with GVRP enabled, you can send a GVRP request using the VID of a VLAN defined on the switch; the switch will automatically add that device t

Página 13 - 3.3 CLI Management

Step4: Follow the same steps to attach the second bracket to the opposite side. Step5: After the brackets are attached to the Switch, use suitable s

Página 14

802.1q VLAN –Add interface 2. Group Name: assign a name for the new VLAN. 3. VLAN ID: fill in a VLAN ID (between 2 and 4094). The default is 1. 4.

Página 15 - 3.3.2 Commands Set List

Click Next Then you will see the page as follow.

Página 16

7. To set the outgoing frames are VLAN-Tagged frames or untagged. Then click Apply button. 。 Tag: outgoing frames with VLAN-Tagged. 。 Untag: outgoi

Página 17 - 3.3.2.2 Port Commands Set

802.1q VLAN - Port VLAN ID interface 4.7.8 Spanning Tree The Spanning-Tree Protocol (STP) is a standardized method (IEEE 802.1d) for avoiding loops i

Página 18

Spanning Tree - System Configuration interface 4.7.8.2 Per Port Configuration You can configure path cost and priority of every port. 1. Select the

Página 19

SPT - Per Port Configuration interface 4.7.9 Port Mirroring The Port mirroring is a method for monitor traffic in switched networks. Traffic through

Página 20

Prot Mirroring interface 4.7.10 SNMP Management The SNMP is a Protocol that governs the transfer of information between management and agent. The swi

Página 21 - 3.3.2.3 Trunk Commands Set

SNMP Management interface Community strings: serve as password 1. Strings: fill the name of string. 2. RO: Read only. Enables requests accompanie

Página 22 - 3.3.2.4 VLAN Commands Set

4.7.11 Security Manager You can change web management login user name and password. 1. User name: type the new user name. The default is "admin&

Página 23

SNTP Configuration Interface 4.7.14 802.1X Configuration When enabling the IEEE 802.1X function, you can configure the parameters of this function.

Página 24

3. CONSOLE MANAGEMENT 3.1 Connecting to the Switch The console port is a female DB-9 connector that enables a connection to a PC or terminal for monit

Página 25

802.1x Configuration - System Configuration interface 4.7.14.2 Per port Configuration 1. Select the port in Port column. 2. Select the state of port

Página 26

request. 5. Max requests: Set the number of authentication that must time-out before authentication fails and the authentication session ends. 6. Re

Página 27

System Log Interface 4.8 TFTP Update Firmware It provides the functions to allow a user to update the switch firmware. Before updating, make sure you

Página 28

4.9 Configuration Backup In Configuration Backup, you can restore the backup configuration into the switch. Also, you can backup the configuration to

Página 29

TFTP Backup Configuration interface 4.10 Factory Default Reset Switch to default configuration, default value to as following configuration: 。 Def

Página 30

4.12 UPS Status You can view connected UPS information and set command to UPS. UPS Status Interface UPS information: the information will be availa

Página 31

¾ Model: model name of the UPS. ¾ Version: UPS internal software version. The figure represents the UPS status, when the status has been detected,

Página 32 - 3.3.2.6 QoS Commands Set

。 Total Power (W): total of all the port power that provided to PD. Port: select the port that you want to configure from the drag down menu in the b

Página 33

5. TROUBLESHOOTING This section is intended to help you solve the most common problems on the 8 10/100TX plus 100FX Exp. Slot managed POE switch. 5.1

Página 34 - 3.3.2.7 IGMP Commands Set

5.2.1 Cabling RJ-45 ports: use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable f

Página 35

bring out the login prompt. Key in the “admin“(default value) for the both User name and Password (use Enter key to switch), then press Enter key and

Página 36 - 3.3.2.9 SNMP Commands Set

6. Appendix 6.1 Console Port Pin Assignments The DB-9 serial port on the front panel is used to connect to the switch for out-of-band console config

Página 37

Cable Type Max. Length Connector 10BASE-T Cat. 3, 4, 5100-ohm UTP 100 m (328 ft) RJ-45 100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft) RJ-45 100

Página 38

information. Privileged EXEC Enter the enable command while in user EXEC mode. switch# Enter disable to exit. The privileged command is advance mode

Página 39 - 3.3.2.11 802.1x Commands Set

3.3.2 Commands Set List 3.3.2.1 System Commands Set Commands Command Level Description Defaults Example system name [systemname] Global configuration

Página 40

default Global configuration mode Restore to default Switch (config)# default username [user-name] Global configuration mode Changes a login usernam

Página 41

show accounting Privileged EXEC Show username & password Switch# show accounting Username: admin Password: admin show version User EXEC Use the s

Página 42

Use the module Ethernet interface configuration command Switch (config)# interface moduleEthernet 1/1 Use the duplex configuration command to speci

Página 43 - Command

for speed 100) (The 1000Base-FX module only supported for speed 1000 & auto) flowcontrol on or no flowcontrol Interface configuration mode Use the

Página 44 - 3.3.2.14 POE Commands Set

Trademarks Copyright © PLANET Technology Corp. 2005. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLAN

Página 45

Bandwidth [in | out] [value] Interface configuration mode Set bandwidth in or out rate. The value rage is (0~999), and zero of the value is disable (T

Página 46 - 3.4 Menu Management

show interface accounting Interface configuration mode show interface statistic counter Switch (config)# interface fastEthernet 0/1 Switch (config-if

Página 47 - 3.4.1 Status and Counters

port group [group-number] [port-list] lacp [on | off] workp [work ports] no port group [group-number] lacp [on | off] workp [work ports] Global conf

Página 48

vlanmode [disable| portbase| 802.1q | gvrp] VLAN database mode To set switch VLAN mode .Use the no form of this command to restore to default. Disable

Página 49 - 3.4.1.3 System Information

[port ID]: port members 1~9 vlan [group name] delete [port ID] VLAN database mode Remove the port from its port group. Switch(vlan)# vlan v2 delete 5

Página 50 - 3.4.2 Switch Configuration

IBM SNA-ibm X.75 internet-x75 X.25 Layer3-x25 NetBIOS-netbios IOS Network Layer PDU -IOS Novell_IPX(raw Ethernet) -ipx_raw Spanning Tree Protocol BPDU

Página 51 - 3.4.2.1.1 Device Information

IBM SNA-ibm X.75 internet-x75 X.25 Layer3-x25 [VLAN ID]: 1 ~ 4094 [port ID]: port ID 1~9(1~26) vlanidrange [VLANidrange] VLAN database mode Set VLA

Página 52 - 3.4.2.1.2 IP Configuration

VLAN protocol [Groupname] add [portNumber] [tagged | untagged] VLAN database mode Set the port of some port group tagged or untagged Switch (vlan)# v

Página 53 - IP Configuration interface

Port Vid: 2 Ingress 1 Filter: Disable Ingress 2 Filter: Enable 3.3.2.5 Spanning Tree Commands Set Commands Command Level Description Defaults Examp

Página 54 - 3.4.1.4.5 SNTP Configuration

spanning-tree [on / off] or no spanning-tree Global configuration mode Use the spanning-tree global configuration command to enable Spanning Tree Pro

Página 55

Table of Contents 1. INTRODUCTION... 5

Página 56 - 3.4.3 Trunk Configuration

receive a bridge protocol data unit (BPDU) message from the root switch within this interval, it recomputes the Spanning Tree Protocol (STP) topology.

Página 57

Protocol (STP) calculations. In the event of a loop, spanning tree considers the path cost when selecting an interface to place into the forwarding st

Página 58 - 3.4.5 VLAN Configuration

stp-path-priority [Port Priority] Interface configuration mode Use the spanning-tree port-priority interface configuration command to configure a port

Página 59 - 3.4.5.1 VLAN Configure

qos level [priority] enable Global configuration mode [Priority] 0~7 0~3 LOW4~7 HI Switch (config)# qos level 2,3 enable no qos level [priority] Globa

Página 60 - 3.4.5.2 Create VLAN Group

show qos low-priority-delay-bound Privileged EXEC mode Show low priority delay board. Switch (config)# show qos low-priority-delay-bound Qos low prio

Página 61

Port 224.1.1.1 10 1,2,6 3.3.2.8 Mac / Filter Table Commands Set Commands Command Level Description Defaults Example mac-address-table aging-time [

Página 62

command to remove static entries from the MAC address table. 004063112233 vlanid 10no mac-address-table [static | filter] hwaddr [MAC address] vlanid

Página 63

snmp system-location [SystemLocation] Global configuration mode Set Snmp agent system location N/A Switch (config)# snmp system-location lab snmp sys

Página 64 - 3.4.6 Priority Configuration

no port monitor Analyzer (SPAN) port monitoring on a port. Use the no form of this command to return the port to its default value. monitor both 3 sho

Página 65 - 3.4.7.1 Static MAC Address

3.3.2.11 802.1x Commands Set Commands Command Level Description Defaults Example show 8021x User EXEC mode Display a summary of the 802.1x properti

Página 66

5. TROUBLESHOOTING... 128 5.1 Incorrect connections

Página 67

8021x system sharekey [Sharekey] Or no 8021x system sharekey Global configuration mode Use the 802.1x system sharekey global configuration command to

Página 68 - 3.4.7.3 Misc Configuration

this command to return to the default interval. 8021x misc txperiod [TXPeriod value] Or no 8021x txperiod Global configuration mode Use the 802.1x

Página 69 - 3.4.8.1 STP

maxrequest authentication session ends. 8021x misc reauthperiod [SEC] Or no 8021x reauthperiod Global configuration mode Set the period of time after

Página 70 - 3.4.8.1.1 STP Setup

state. 3.3.2.12 TFTP Commands Set Commands Command Level Description Defaults Example copy flash:config.tetftp [TFTP IP addressxt ] [file name] n m

Página 71 - 3.4.8.1.3 Per Port Setting

UPS status. put Output Voltage like web information In Info UPS mode Show UPS information Switch (ups)# info ame :xxx Version :xxx Company NModel :x

Página 72 - 3.4.8.2 SNMP

setlimit POE mode Enabling or disabling total power output limit. When is enabling, the total power output limit will follow the value that set in pow

Página 73 - 3.4.8.2.2 Community Strings

portpri POE mode Set port priority for the power supply management. Switch (poe)# portpri Set Port [1~8]=1 Set Port 19847000 Priority (1:Critical, 2:

Página 74 - 3.4.8.2.3 Trap Managers

。 System Reset Configuration: Restart the system or reset switch to default configuration. 。 UPS menu: configure the UPS function. 。 POE menu: conf

Página 75

Status and Counters main configuration interface 3.4.1.1 Port Status It displays status of each port. Select the <Previous Page> action to disp

Página 76 - 3.4.8.3 LACP

Port status display interface 3.4.1.2 Port Counters It displays the current port counter information. Select the <Refresh> to get newest counte

Página 77

1. INTRODUCTION 1.1 Packet Contents Check the contents of your package for following parts: ▫ Fast Ethernet PoE Switch x1 ▫ CD-ROM user's manu

Página 78 - 3.4.8.3.3 LACP Group Status

。 System Location: where the device is located. 。 System Description: the name of device type. 。 Firmware Version: the switch's firmware versi

Página 79 - 3.4.8.5 802.1x Configuration

Switch Configuration interface 3.4.2.1 Administration Configuration In Administration Configuration, you can configuration system parameter, IP, logi

Página 80 - 3.4.8.5.3 Per Port Setting

2. Description: a short description for the switch. 3. Location: the switch location, ex: Taipei. 4. Contact: the contact person or information. 5.

Página 81 - 3.4.8.5.4 Misc Configuration

IP Configuration interface 3. 4.2.1.3 User Name Configuration You can change the console and web management login user name. 1. Select the <Edit&

Página 82 - 3.4.9.1 Factory Default

1. Select the <Edit> 2. Old Password: enter the old password. 3. New Password: enter the new password. 4. Enter Again: reenter the new passwo

Página 83 - 3.4.9.3 TFTP Configuration

SNTP Configuration Interface 3.4.1.4.6 Syslog Client Configuration You can configure the switch as the system log client that can view the system log

Página 84

3.4.2 Port Configuration You can set up every port status. 1. Select <Edit> 2. Use "Tab/Backspace" key to move between items. 3. Stat

Página 85

5. Apply the configuration by selecting <Apply>. Trunk Configuration interface 3.4.4 Port Mirroring Configuration The port mirroring is a meth

Página 86 - 3.4.10 UPS Menu

Port Mirroring interface 3. Analysis port: Set the destination port of mirroring packet. All of the packets of mirroring port will be duplicated and

Página 87 - 3.4.11 POE Menu

mode: VLAN Configuration, Create a VLAN Group, Edit/Delete VLAN Group and Group Sorted Mode. Follow the below description to configure VLAN. VLAN Con

Página 88

Gigabit fiber, 802.3af power over Ethernet ▫ High back-plane bandwidth 8.8Gbps ▫ IGMP snooping and IGMP Query mode for Multi-media application

Página 89

VLAN Configure interface 3.4.5.2 Create VLAN Group Create Port-Based VLAN 1. Select <Edit>. 2. VLAN Name: Type a name for the new VLAN, ex: VL

Página 90 - 3.4.13 Xmodem Upgrade

Create VLAN Group: PortBase interface Create 802.1Q VLAN 1. Enable security VLAN setting: select to enable or disable security VLAN group. When you

Página 91

3. VLAN Name: Type a name for the new VLAN, ex: VLAN01. 4. VLAN ID: Type a VID. The default is 1. There are 256 VLAN groups to provided configure. 5

Página 92 - 4. WEB-BASED MANAGEMENT

1. The VLAN Name and VLAN ID cannot modify. 2. In 802.1Q VLAN mode, the default VLAN can't be deleting. 3. In Port Base VLAN mode, there is no

Página 93 - 4.5 Port status

Group Sorted Mode interface 3.4.6 Priority Configuration You can configure port priority level. There are 0~7-priority level can map to high or low qu

Página 94 - 4.6 Port Statistics

3.4.7 MAC Address Configuration When you add a static MAC address, it remains in the switch's address table, regardless of whether the device is

Página 95 - 4.7 Administrator

Add Static MAC Address interface Edit static MAC address 1. Press <Edit>. 2. Choose the MAC address that you want to modify and then press &qu

Página 96 - 4.7.2 Switch Setting

Filtering MAC Address interface Add the Filtering MAC Address 1. Select <Add> --> <Edit> key to add the static MAC address. 2. MAC A

Página 97 - 4.7.2.2 Advanced Setting

3. Select <Edit> key to modify. 4. Press "ESC" to go back action menu line 5. Select <Apply> to apply all configure value. De

Página 98 - 4.7.2.3 Misc Configuration

Misc Configuration interface 3.4.8 Protocol Related Configuration You can configure Spanning Tree Protocol, SNMP, LACP, IGMP/GVRP, and 802.1x in Prot

Página 99

100FX module (module)): Link/Activity, Full duplex Remote power feeding End-point insert type and compatible with IEEE802.3af Per port feeding power:

Página 100 - 4.7.4 Port Controls

loops in the network. STP Configuration interface 3.4.8.1.1 STP Setup You must enable Spanning Tree function before configuration. 1. Select <Edit

Página 101 - 4.7.5 Trunking

3.4.8.1.2 System Configuration You can configure the STP system parameter after enable the STP function. You can view spanning tree informationa about

Página 102 - "Note:

Per Port Setting interface 3.4.8.2 SNMP To define management stations as trap managers and to enter SNMP community strings. You can also define a nam

Página 103 - 4.7.6.1 IGMP Snooping

4. Location: Type the location of the switch. 5. Press “ESC” goes back action menu line. 6. Press <Apply> to apply configuration value. SNMP S

Página 104 - 4.7.6.2 Static MAC Address

Add Community Strings interface Edit SNMP Community 1. Select <Edit> 2. Choose the item that you want to modify and then press “Enter”. 3. C

Página 105

Trap Managers interface Add the trap manager 1. Select <Add> -> <Edit> to add the trap manager. 2. IP: type the IP address. 3. Commu

Página 106 - 4.7.7 VLAN configuration

2. Choose the trap manager that you want to delete and then press “Enter”. 3. When pressing “Enter” will complete deletion. 3.4.8.3 LACP The Link Agg

Página 107

LACP Working Ports configuration interface 3.4.8.3.2 LACP State Activity 1. Select <Edit> 2. Use “Space” key to select the Port State Activity.

Página 108 - 4.7.7.2 802.1Q VLAN

3.4.8.3.3 LACP Group Status When you are setting trunk group, you can see the relation information in here. LACP Group State interface 3.4.8.4 IGMP/G

Página 109

3.4.8.5 802.1x Configuration You can configure 802.1x relate settings. 802.1x Configuration interface 3.4.8.5.1 802.1x Setup 1. Select <Edit> 2

Página 110

2. INSTALLATION This section describes the functionalities of the Switch's components and guides how to install it on the desktop or shelf. Basic

Página 111

1. Select <Edit> 2. Radius Server IP: set the Radius Server IP address. 3. Shared Key: set an encryption key for using during authentication s

Página 112 - button

802.1x Per Port Setting interface 3.4.8.5.4 Misc Configuration 1. Select <Edit> 2. Quiet period: set the period during which the port doesn’t

Página 113 - 4.7.8 Spanning Tree

802.1x Misc Configuration interface 3.4.9 System Reset Configuration System Reset Configuration interface 3.4.9.1 Factory Default Reset switch to de

Página 114

Factory Default interface 3.4.9.2 System Reboot Reboot the switch in software reset. 3.4.9.3 TFTP Configuration It provides user to update firmware o

Página 115 - 4.7.9 Port Mirroring

2. Select <Edit>. 3. TFTP Server IP: type the IP of TFTP server. 4. Firmware File Name: type the image file name. 5. Press "ESC" goe

Página 116 - 4.7.10 SNMP Management

TFTP Restore Configuration interface 3.4.9.3.3 TFTP Backup Configuration You can save current EEPROM value to TFTP server as backup. The backup file

Página 117

TFTP Backup Configuration interface 3.4.10 UPS Menu You can view connected UPS information and set command to UPS. UPS information display area UPS

Página 118 - 4.7.13 SNTP Configuration

。 Bty. Cap.: display the battery capacity of UPS. 。 Overload: display the overload capacity of UPS. 。 Temperat.: display the current temperature of

Página 119 - 4.7.14 802.1X Configuration

POE management Power Supply management 。 Port Enable: display the POE port status. Y means the port is enabling. N means the port is disabl

Página 120 - 4.7.14.3 Misc Configuration

¾ R detect: When the port doesn't connect with any PD, the POE switch will poll each port and detects the resistor. 。 Dsvry R (ohms): display r

Página 121 - 4.7.15 System Log

2.1.2 Switch Front Panel Figure 2-1 shows the front panel of the switch. Figure 2-1 WGSW-2620PV front panel. 2.1.3 LED Indications Network/PoE: LED

Página 122 - 4.8 TFTP Update Firmware

[t] Set Total Power Limit Set the total port power limit. When the Power Management is enabling, this function will show up. [0] Exit Exit POE Menu mo

Página 123 - 4.9 Configuration Backup

6. After successfully upgraded the new firmware, please modify baud rate to 9600bps.

Página 124 - 4.11 System Reboot

4. WEB-BASED MANAGEMENT This section introduces the configuration and functions of the Web-Based management. The following configuration descriptions

Página 125 - 4.12 UPS Status

4.4 System Login 1. Launch the Internet Explorer. 2. Type "http://" and the IP address of the WGSW-2620PV and press "Enter". 3.

Página 126 - 4.13 POE Status

9. Port Security: display the port security is "enable" or "disable". Port Status interface 4.5.1 View the Port Information Yo

Página 127

ports statistics. Click Clear button to clean all counts. Port Statistics interface 4.7 Administrator In Administrator function, it provides the f

Página 128 - 5. TROUBLESHOOTING

can set the IP address back to its default IP address or you can reset the switch back to factory default. And then you can enable the DHCP client fun

Página 129 - 5.3 Diagnosing POE problems

Switch basic setting interface 4.7.2.2 Advanced Setting Queue Service. After the configuration, click Apply button to complete the configuration. 

Página 130 - 6. Appendix

Switch Advanced setting interface  Priority Queue Service settings: select the priority queue service type. 。 First Come First Service: the seque

Página 131

Query will be the first priority. The modes are: A. Auto Mode: chooses the switch that has the smallest IP address to be set for the IGMP Query mode.