User's Manual GT-902 GT-902S GT-905A GT-906A15 / GT-906B15 GT-906A60 / GT-906B60 10/100/1000Base-T to 1
2. HARDWARE DESCRIPTION This product provides three different running speeds – 10Mbps, 100Mbps and 1000Mbps in the same Managed Media Converter and a
2.1.1 LED Indicators LED Color Description PWR Green Lit: When +5VDC power detected. Lit: To indicate the link through that fiber port is succes
2.2 Install the Converter This section describes how to install your Managed Media Converter and make connections to the Managed Media Converter. Ple
#Notice: Please refers to APPENDIX-A for detailed wiring information of the Managed Media Converter. To prevent from optic acceptor malfunction, chec
2.2.2 Chassis Installation and Rack Mounting To install the Managed Media Converter in a 10-inch or 19-inch with standard rack, follow the instructio
Figure 2-6 Mounting the Chassis in a Rack -11-
3. MEDIA CONVERTER MANAGEMENT This chapter describes how to manage the Managed Media Converter. Topics include: - Overview - Management methods -
3.2.1 Web Management The PLANET Managed Media Converter provides a built-in browser interface. You can manage the Managed Media Converter remotely by
3.2.3 PLANET Smart Discovery Utility For easily list the Managed Media Converter in your Ethernet environment, the Planet Smart Discovery Utility fro
3. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version, Device IP Subnet address, also c
-2- Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to which revision without prior notice. PLANET is a registered trademark of
4. WEB MANAGEMENT The GT-90X Managed Media Converter provide Web interface for management function configuration and make the Managed Media Converte
4.2 System 4.2.1 System Information The System Information Web page provides information for the current device. System Information Web page helps ne
4.2.2 IP Configuration The IP Configuration includes the DHCP Client, IP Address, Subnet Mask, Gateway and Description. The screen in Figure 4-3 appe
4.2.3 Password Setting This function provides administrator to secure Web login. The screen in Figure 4-4 & 4-5 appears and Table 4-3 describes t
The Password Setting Web page includes the following configurable data: Login Name Displays the user name (admin). Old Password Enter the old passwor
Press “Browser” button to find the firmware location administrator PC, The screen in Figure 4-7 appears Figure 4-7 Firmware Upgrade Web page screen
Figure 4-9 Firmware Upgrade Web page screen When firmware upgrade process is completed then the following screen appears, please click “here” to re
Figure 4-11 Login Web page screen -23-
4.2.5 SNMP Management This function provides SNMP Management and SNMP Trap Receiver Configuration function of the Managed Media Converter and the scr
Figure 4-13 SNMP Trap Receiver Configuration Web page screen The SNMP Trap Receiver Configuration Web page includes the following configurable data
-3- TABLE OF CONTENTS 1. INTRODUCTION ...
4.2.6 Factory Default This function provides Factory Default function of the Managed Media Converter and the screen in Figure 4-14 & 4-15 & 4
Figure 4-16 Login Web page screen 4.2.7 System Reboot This function provides System Reboot function of the Managed Media Converter and the screen in
Figure 4-18 System Reboot Web page screen Figure 4-19 Login Web page screen -28-
4.3 Port Management 4.3.1 Port Configuration This function allows displaying TP / Fiber port status. The Link Status in the screen displays the curre
Flow Control Allow Disable or Enable Flow Control of TP or Fiber port. • Enable – IEEE 802.3x Flow Control is enabled on Full-Duplex mode or Backpres
Figure 4-21 Port Configuration-Ingress Rate Limit Web Page screen Figure 4-22 Port Configuration-Egress Shaping Web Page screen -31-
4.3.2 Port Status This function allows displaying TP / Fiber port detail status, such as Link Status, Duplex Mode, Flow control, Speed and Auto negot
4.3.3 Port Statistics This function allows displaying TP / Fiber port detail Statistics, press the “Clear” button to clear current counter informatio
4.4 Converter Configuration This function provides useful setting for the Managed Media Converter, such as Maximum Packet length, Loop detection, sto
Storm Filter Timer Provide storm Filter Timer setting and the available options are: 800ms 400ms 200ms 100ms Default mode is 800ms. Apply button Pr
-4- 4.5.3 Q-in-Q VLAN Setting...
802.1Q Tag User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits TPID (Tag Protocol Identifier) TCI (Tag Control Information) 2 bytes 2 by
Default VLANs The Managed Media Converter initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all
Figure 4-28 VLAN Group Web Page screen The VLAN Group Web page includes the following configurable data: VLAN Mode Provide Disable or enable the IEE
4.5.2 VLAN Per Port Setting This function provides IEEE 802.1Q VLAN per port setting for TP and Fiber port of Managed Media Converter. Press the “App
4.5.3 Q-in-Q VLAN Setting When enable Q-in-Q function, Managed Media Converter can insert or remove 4-bytes Q-in-Q tag in the received 802.3 frames
4.6 Quality of Service Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traff
The Quality of Service Web page includes the following configurable data: Qos Mode Provide 4 different QoS mode for operation, the available options
Figure 4-33 IP Address Priority Web Page screen Figure 4-34 IP DSCP Priority Web Page screen -43-
4.7 OAM Setup 4.7.1 Local TS-1000 OAM Setup This function provides Local TS-1000 OAM Setup of Managed Media Converter. Press the “Apply” button to sa
4.7.2 Remote TS-1000 OAM Setup The Remote TS-1000 OAM Setup is an advanced remote device monitor feature that allows you to Remote monitor and automa
1. INTRODUCTION 1.1 Package Contents Check the contents of your package for following parts: ● Managed Gigabit Ethernet Media Converter x1 ● CD-ROM
Figure 4-37 GT-90x Remote TS-1000 OAM Setup Web Page screen #Notice: Please use the PLANET GT-80x and GT-90x as the Remote device.
4.7.3 TS-1000 Loop Back Test The TS-1000 Loop Back Test allows manual run this loop back test to check the interconnection between two Media Converte
Figure 4-38 Remote TS-1000 Loop Back Test Web Page screen The TS-1000 Loop Back Test Web page includes the following configurable data: TS-1000 Loop
4.7.4 802.3ah Setup When enable 802.3ah OAM function, all 802.3ah OAMPDU packets will trap to embedded CPU. Software will implement auto discovery pr
#Notice: 1. The 802.3ah function must work with manageable device that supports 802.3ah function. 2. Please use the PLANET GT-90x as the Remote devi
Figure 4-40 802.3ah Loop Back Test Web Page screen The 802.3ah Loop Back Test Web page includes the following configurable data: 802.3ah Loop Back T
4.8 Security This function provides TCP / UDP Filter setting of Managed Media Converter. Press the “Apply” button to save the current configuration o
4.9 Logout This function provides Logout function of Managed Media Converter, when the “Are you sure to logout” pop window appears; press the “OK” bu
5. TROUBLESHOOTING This chapter contains information to help you solve problems. If the media converter is not functioning properly, make sure the me
APPENDIX A NETWORKING CONNECTION A.1 Device‘s RJ-45 Pin Assignments 1000Mbps, 1000Base T RJ-45 Connector pin assignment Contact MDI MDI-X
-2- 1.3 About the Managed Media Converter The Managed Media Converter GT-90x provide conversion between 10/100/1000Base-T and 1000Base-SX /LX networ
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and cr
-57- A.4 Power Information The power jack of Managed Media Converter is with 2.5mm in the central post and required +5VDC power input. It will confor
PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. T
1.4 Product Features Complies with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z 1000Base-SX/LX O
; TS-1000 OAM / IEEE 802.3ah OAM / Loop Back Test ; 16 TCP / UDP Filter groups ; Password setting, IP setting and devices description setting thro
Power Consumption 3.8 Watts/ 13 BTU (maximum) Power Input DC 5V / 2A Dimensions 94 x 70 x 26mm (W x D x H) Operator Environment Operating temper